GC Instrument Control Software: Set Up Your Gas Chromatograph from Chromperfect

Writer: Chromperfect
Chromperfect
14 hours ago
4 min read

How much of your GC setup still happens at the front panel? Oven programs, inlet pressures, detector settings and valve times keyed in by hand are easy to get wrong, and hard to repeat exactly. Chromperfect's GC instrument control software sets up the gas chromatograph for you. It uploads the GC's setpoints, lets you edit them in the File Editor, and downloads them with the method before the run. Watch the three-minute overview, then read on for the details.



What is GC instrument control software?


Digital instrument control means your chromatography data system talks to the chromatograph itself, not just to its detector signal. Chromperfect connects to the GC over a serial (RS-232) or network (TCP/IP) connection. The instrument's operating conditions are kept in a Chromperfect setpoint file, and the method that runs your samples names that file. Download the method, and Chromperfect sets the GC to those conditions before the run starts.


The result is GC setup that is part of the method: uploaded once, checked once, and repeated exactly, run after run.


Which GCs does Chromperfect control?


Chromperfect's GC instrument control software works directly with:


  • Agilent GCs from the HP 5890 to the 6890, 6850 and 7890

  • Thermo Trace GCs

  • PerkinElmer Clarus GCs

  • Teledyne Falcon GCs


Through the Agilent Instrument Control Framework (ICF), it also controls the Agilent 8890 and Intuvo, and GCs from Shimadzu and Scion. Each instrument type has its own setpoint format: MXT for the HP 5890, M68 for the 6890 and 6850, M78 for the 7890, MTE for the Thermo Trace, MFL for Falcon, MCS for the PerkinElmer Clarus, and MIC for ICF GCs and LCs.


GC instrument control software showing an Agilent 8890 oven program in a Chromperfect MIC setpoint file
An Agilent 8890 setpoint (MIC) file open in Chromperfect, edited through the Agilent Instrument Control Framework.

Upload the settings you already trust


You don't start from a blank page. Set the GC up the way you want it, then upload its current setpoints into a setpoint file. For an Agilent 7890, open the instrument's Special Features form in the Acquisition program, enter a Setpoint File Name on the Upload tab and press Upload. Chromperfect reads the settings from the GC and saves them as a snapshot of the instrument.


Setpoint files belong to the instrument that created them, which is why the first file is uploaded rather than created from a blank template. One point to remember: the instrument must have been downloaded with a method first, because setpoints can't be uploaded while it shows Awaiting Download.


Chromperfect HP7890 Special Features Upload tab with the setpoint file name Sample.m78 and the Upload button
The Upload tab of the HP7890 Special Features form saves the GC's current setpoints to a setpoint file.

Edit oven ramps, pressures, detectors and valve events


Open the setpoint file in the Chromperfect File Editor (File, Open, then the setpoint file button for your instrument type) and every setting is there. The editor for an Agilent 7890 setpoint file has tabs for the oven, inlets, pneumatics, columns, detectors, auxiliary zones, timed events, valves, injectors, the autosampler tray and signals.


Temperature, pressure and flow programs are edited in the ramp editor, which draws the program as you change it: the initial time and temperature, each ramp and hold, and the total program time. Timed events switch valves at set times during the run. These are GC events, separate from the integration events in a Chromperfect method.


Need a variation for another application? Change the settings and use Save As to keep it under a new name, so each analysis has its own setpoint file.


Chromperfect File Editor showing the 7890 setpoint file tabs and an oven temperature program ramp graph
An Agilent 7890 setpoint file (Sample.m78) in the File Editor, with the oven program open in the ramp editor.

The method carries the instrument settings


Next, name the setpoint file in a Chromperfect method. On the Acquisition tab of the Method file, choose the setpoint type for your instrument under Download Setpoint File and select the setpoint file. When you download that method, Chromperfect sets the GC to those conditions before the run.


Run a sequence, and each method brings its own setpoints. There's no retyping and no transcription errors, and the instrument conditions are stored with the method that uses them. If the same setpoint file would be downloaded again and again during a sequence, the download form lets you send it every time or only when the file name changes.


Chromperfect method file Acquisition tab with HP7890 selected and Sample.m78 as the setpoint file name
The Acquisition tab of a Chromperfect method names the setpoint file that is downloaded to the GC.

Safeguards for your column


With some gas chromatographs, downloading the wrong setpoint file can damage the column. Chromperfect lets you restrict a method to named instruments. Put the instrument name in square brackets in the method's Description field, for example "Volatiles method for [GC-1]", and tick "Require instrument name in Method file Description field" in the download form. The method then can't be downloaded to any other instrument. You can also restrict a method to a detector, as in [GC-1 | FID].


Permissions decide who may download instruments or write setpoint files, and the data log records each time a user downloads an instrument or writes a setpoint file.


Chromperfect download form with the option to require the instrument name in the method description highlighted
The download form's "Require instrument name in Method file Description field" option keeps a method on the instruments it was written for.

Run it from your desk


Once the GC is set up, the Instrument Control form lets you start, stop or abort a run, download the instrument and change the run time from Chromperfect. For supported Agilent GCs, Special Features adds three more views: GC Features lists the installed inlets and detectors, Readiness shows what is keeping the GC from being ready, and Front Panel mirrors the GC's front panel display. A claimed instrument can be controlled from any Chromperfect station on your network.


Chromperfect Acquisition program Instrument Control form with Start Run, Stop Run, Download and Abort Run buttons
The Instrument Control form starts, stops and aborts runs and downloads the instrument from your desk.

Key points


  • Chromperfect's GC instrument control software connects directly to supported GCs over serial or network connections, and to ICF instruments through the Agilent Instrument Control Framework.

  • Upload the GC's current setpoints into a setpoint file, then edit oven, inlet, detector and valve settings in the File Editor.

  • Name the setpoint file in a method, and the GC is set to those conditions whenever the method is downloaded.

  • Restrict methods to named instruments to protect your columns, and use permissions and the data log for control and traceability.

  • Start, stop and abort runs, and see the GC's readiness, from any Chromperfect station.


Is your GC supported?


To find out whether your gas chromatograph is supported, visit chromperfect.com or send us the make and model. For a step-by-step guide to setpoint files, see our post and video Chromperfect Instrument Setpoint Files: How to Upload, Open and Edit Them Correctly.