Flat Top Chromatography Peak: Detector Saturation, Signal Clipping and Other Causes
If a chromatography peak suddenly develops a flat top, detector overload is an obvious suspect — but it is not the only possible cause. A flat top chromatography peak can originate in the detector itself, in the analog data acquisition hardware, or, in one specific historical case, within the chromatography data system. Correctly identifying where the signal is being limited matters because each cause requires a different solution. Diluting a sample will not correct an acqui

Chromperfect
Aug 136 min read


Chromperfect Supported Instruments: Digital Connections, Analog Options, and What to Do When Your Instrument Is Not Listed
Chromperfect supports a range of chromatography instruments through native digital drivers and ICF/RC.NET. Instruments without a supported digital connection may still be usable through analog acquisition with a Tigre interface, provided suitable detector output, signal voltage and remote-start connections are available.

Chromperfect
Aug 75 min read


Chromperfect Instrument Setpoint Files: How to Upload, Open and Edit Them Correctly
Learn how to upload, open and edit Chromperfect instrument setpoint files correctly, understand instrument-specific editors such as MIC and 7890 forms, and resolve the Awaiting Download status.

Chromperfect
Aug 15 min read


Displaying a Component Without Calibrating It in Chromperfect
Excerpt:
How to keep a component visible in a Chromperfect calibration file or chromatogram plot without treating it as an active calibrated analyte.

Chromperfect
Jun 133 min read


Understanding GC/MS Support in Chromperfect - Gas Chromatography vs Mass Spectrometry
A clear explanation of GC/MS support in Chromperfect, including why Chromperfect can support applicable GC acquisition but does not support mass spectrometers or MS data acquisition.

Chromperfect
Jun 122 min read


Understanding GC Configuration and Setpoint Files in Chromperfect
Understand the difference between GC configuration and Chromperfect GC setpoint files, including why some visible instrument settings cannot be changed directly from Chromperfect.

Chromperfect
Jun 104 min read


Chromperfect Beginner Training Series:
A complete overview of the Chromperfect Beginner Training Series, covering all sections and chapters from system foundations through to reporting and automation, with a full playlist of 20+ training videos designed to guide users through real laboratory workflows.

Chromperfect
Apr 74 min read


Installing Chromperfect on a Replacement Computer: Migration, Setup, and Common Pitfalls
Replacing a Chromperfect computer requires reinstalling the software and carefully restoring data and configuration. This guide explains what can be reused, what must be reconfigured, and how to avoid common migration issues.

Chromperfect
Feb 73 min read


Chromperfect Licensing Explained: What You Own, What Expires, and What Doesn’t
Chromperfect uses perpetual licensing — not subscriptions. This article explains how Chromperfect licenses work, what never expires, what can change over time, and how to avoid common licensing pitfalls.

Chromperfect
Jan 284 min read


Chromperfect Microsoft Surface Compatibility: Windows x64 vs Windows on ARM Explained
An explanation of Chromperfect compatibility on Microsoft Surface devices, clarifying the difference between Windows x64 and Windows on ARM and outlining which systems are officially supported.

Chromperfect
Jan 283 min read


Chromperfect Windows Compatibility: Version History and Alignment
Chromperfect Windows compatibility timeline illustrating the evolution from MS-DOS to Windows 11 and long-term data integrity.

Chromperfect
Jan 273 min read


Understanding Chromperfect Products and Licensing
A clear overview of Chromperfect products and licensing, explaining software licenses, instrument connections, digital and analog systems, data analysis options, and supported versions.

Chromperfect
Dec 29, 20253 min read


A Closer Look at Chromperfect 10 and the Benefits It Brings to Your Laboratory
Chromperfect 10 introduces secure data locking, expanded instrument compatibility, HTA autosampler support, and full Windows 11 optimisation — making it a strong choice for both new CDS adopters and existing Chromperfect users.

Chromperfect
Dec 11, 20253 min read


Why an Independent Chromatography Data System Matters: Unbroken File Compatibility Since 1982
Excerpt from the Chromperfect video showing a file icon with an infinity symbol, representing unbroken chromatography data compatibility from MS-DOS to Windows 11.

Chromperfect
Dec 10, 20254 min read


Compliance Made Simple: CFR 21 Part 11 Built Into Chromperfect 10
Chromperfect 10 delivers full CFR 21 Part 11 compliance, with secure data locking, complete audit trails, and simplified validation — no more workarounds or unsecured files.

Chromperfect
Aug 15, 20251 min read


Improved Support for Thermo 1300 and 1600 Series GCs in Chromperfect 10
Chromperfect 10 enhances native driver support for Thermo 1300 and 1600 series gas chromatographs, improving performance, reliability, and adding Auxiliary Oven support for expanded capabilities.

Chromperfect
Aug 15, 20251 min read